BLHTF - SS 330 & 330C DUNCAN SUPER GLOSS CERAMIC SE

  • MSDS: BLHTF
  • Manufacturer: DUNCAN ENTERPRISES
  • Product Name: SS 330 & 330C DUNCAN SUPER GLOSS CERAMIC SE
  • National Stock Number: 8010-00N020156
Product Identification

Product ID:SS 330 & 330C DUNCAN SUPER GLOSS CERAMIC SE
MSDS Date:04/01/1991
FSC:8010
NIIN:00N020156
MSDS Number: BLHTF

Responsible Party
DUNCAN ENTERPRISES
5673 E SHIELDS AVE
FRESNO, CA 93727
US

Emergency Phone: 209-445-1222

Info Phone: 209-291-4444

Cage: 21546

Contractor
DUNCAN ENTERPRISES
FRESNO, CA 93727 US

Telephone: 209-291-4444

Cage: 21546

Ingredients

TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 20 - 25%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


P-NITROCHLOROBENZENE

CAS: 100-00-5

RTECS: CZ1050000

Fraction By Weight: 10%

OSHA PEL S, 1 MG/M3

ACGIH TLV: S, 0.64 MG/M3; 9192


N-BUTYL ACETATE (SARA III)

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 5%

OSHA PEL 150 PPM/200 STEL

ACGIH TLV: 150 PPM/200STEL;9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: <5%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2-BUTOXYETHANOL

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: >5%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM; 9293


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 15%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LPG (LIQUEFIED PETROLEUM GAS)

CAS: 68476-85-7

RTECS: SE7545000

Fraction By Weight: 25%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM; 9192

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:RPTS HAVE ASSOC RPTD/PRLNG OVEREXP TO
SOLV W/PERMANENT BRAIN/NERV SYS DMG, ALSO KIDNEY/LIVER DMG. NIOSH
STUDIES INDICATE 2-BUTOXYETHANOL HAS CAUSED REPRO DISORDERS IN LAB
ANIMALS (RATS/ MICE) & MAY HA VE POTNTL FOR CAUSING SIMILAR
DISORDERSIN HUMANS . IN CONFINED AREA VAPS IN HIGH CONC ARE
ANESTH.(EFTS OF OVEREXP
Explanation of Carcinogenicity:METHYLENE CHLORIDE:CLASS 2 (NTP);CLASS
2B (IARC)
Effects of Overexposure:HLTH HAZ:IRRIT TO SKIN/UPPER RESP SYS. OVEREXP
MAY RESULT IN LT HEAD, STAGG GAIT, GIDD/POSS NAUS. CONTAINS PETRO
DISTIL. HARMFUL/FATAL IF SWALLOWED. CHLOROCARBON MATL HAVE PROD
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE
SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE)MAY BE
(SUPDAT)
Medical Cond Aggravated by Exposure:CARDIOVASCULAR PROBLEMS MAY BE
AGGRAVATED BY OVEREXPOSURE TO METHYLENE CHLORIDE.

First Aid

First Aid:INHAL:REMOVE PATIENT TO FRESH AIR. CONSULT MD. EYES:FLUSH
WITH WATER FOR AT LEAST 15 MINUTES. CONSULT MD. SKIN: WASH WITH
SOAP AND WATER. CONSULT MD. INGEST:CALL MD IMMEDIATELY. DO NOT
INDUCE VOMITING .

Fire Fighting

Flash Point Method:TOC
Flash Point:<20F,<-7C
Lower Limits:SEE ING
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE - WATER MAY BE USED
TO KEEP FIRE EXPOSED CONTAINER COOL. USE NIOSH/MSHA APPROVED
PRESSURE DEMAND SCBA AND FULL PROT EQUIP .
Unusual Fire/Explosion Hazard:DO NOT SPRAY NEAR OPEN FLAME. KEEP AT
ROOM TEMP AS EXPOS TO DIRECT SUNLIGHT/OTHER HEAT MAY CAUSE
BURSTING. THRMAL DECOMP PROD MAY INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE.
AVOID BREATHING VAPORS AND REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. KEEP AT ROOM
TEMPERATURE AS EXPOSURE TO DIRECT SUNLIGHT OR HEAT MAY CAUSE
BURSTING.
Other Precautions:KEEP AWAY FROM CHILDREN. DO NOT PUNCTURE/INCIN. DO
NOT SPRAY NEAR FIRE/OPEN FLAME. SUBJECT TO SARA TITLE III, SEC
313;40 CFR 372; AND CALIF PROP 65. NO SMOKING IN AREA OF USE. DO
NOT USE IN GEN VICINI TY OF ARC WELDING, OPEN FLAMES/(SUPDAT)

Exposure Controls

Respiratory Protection:AVOID BRTHG OF VAP/SPRAY MIST. IF PERSONAL EXPOS
CANNOT BE CONTROLLED BELOW APPLIC LIM BY VENT, WEAR A NIOSH/MSHA
APPRVD PROPERLY FITTED ORGANIC VAP/PARTICULATE RESP FOR PROT. WHEN
SANDING/ ABRADING F RIED FILM, WEAR NIOSH/MSHA APPRVD(SUPDAT
Ventilation:PROVIDE LOC EXHAUST VENT IN VOL & PATTERN TO KEEP TLV BELOW
ACCEPTABLE LIMIT, & LEL BELOW STATED LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP:CONTRAINDICATED EXCEPT FOR LIFE SUSTAINING USES IN
HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS . OTHER PREC:HOT
SURF. HEAT &/OR UV RADIA MAY CAUSE FORM OF HCL &/OR PHOSGENE .
RESP PROT:DUST/MIST RESP APPRVD FOR DUST WHICH MAY BE GENERATED
FROM THIS PROD, UNDERLYING PAINT/ABRASIVE.

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:0F,-18C
Vapor Pres:52 PSIG
Vapor Density:>AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:COATINGS
Percent Volatiles by Volume:84(WT)

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:DO NOT STORE ABOVE 120F
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
HYDROGEN CHLORIDE, AND PHOSGENE GAS.

Disposal

Waste Disposal Methods:DO NOT INCINERATE. DISPOSE OF IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REGULATIONS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.